Commands
5-11
IM 760101-11E
5
Command
Function
Page
:WAVeform:SRATe?
Queries the sampling rate of the retrieved waveform.
5-84
:WAVeform:STARt
Sets the output start point of the waveform display data that is transmitted by
“
:WAVeform:SEND?
” or queries the current setting.
5-84
:WAVeform:TRACe
Sets the target waveform for the
WAVeform:SEND and WAVeform:LENGth
commands or queries the current setting.
5-84
:WAVeform:TRIGger?
Queries the trigger position of the retrieved waveform.
5-84
WSETup (Wave SETup) Group
:WSETup?
Queries all settings related to the waveform observation.
5-86
:WSETup:POSition?
Queries all settings related to the vertical position (GND position) of the
waveform.
5-86
:WSETup:POSition:{UALL|IALL}
Collectively sets the vertical position (level of the center position) of the
waveform
{voltage|current}
of all elements.
5-86
:WSETup:POSition:{U<x>|I<x>}
Sets the vertical position (level of the center position) of the waveform
{voltage|current}
of the element or queries the current setting.
5-86
:WSETup[:SAMPling]
Turns ON/OFF the waveform sampling or queries the current setting.
5-86
:WSETup:TDIV
Sets the Time/div value of the waveform or queries the current setting.
5-86
:WSETup:TRIGger?
Queries all settings related to the trigger.
5-86
:WSETup:TRIGger:LEVel
Sets the trigger level or queries the current setting.
5-86
:WSETup:TRIGger:MODE
Sets the trigger mode or queries the current setting.
5-86
:WSETup:TRIGger:SLOPe
Sets the trigger slope or queries the current setting.
5-86
:WSETup:TRIGger:SOURce
Sets the trigger source or queries the current setting.
5-87
:WSETup:VZoom?
Queries all settings related to the vertical zoom factor of the waveform.
5-87
:WSETup:VZoom:{UALL|IALL}
Collectively sets the vertical zoom factor of the waveform
{voltage|current}
of all elements.
5-87
:WSETup:VZoom:{U<x>|I<x>}
Sets the vertical zoom factor of the waveform
{voltage|current}
of the element or queries the current setting.
5-87
Common Command Group
*CAL?
Executes zero calibration (zero level compensation, same operation as
pressing CAL (SHIFT+MEASURE)) and queries the result.
5-88
*CLS
Clears the standard event register, extended event register, and error queue. 5-88
*ESE
Sets the standard event enable register or queries the current setting.
5-88
*ESR?
Queries the standard event register and clears the register.
5-89
*IDN?
Queries the instrument model.
5-89
*OPC
Sets a “1” to bit 0 (OPC bit) of the standard event register upon the
completion of the specified overlap command.
5-89
*OPC?
ASCII code “1” is returned when the specified overlap command is completed. 5-89
*OPT?
Queries the installed options.
5-89
*PSC
Sets whether to clear the following registers at power up or queries the current
setting. Clears the register when the value rounded to an integer is not zero. 5-89
*RST
Executes the initialization of settings.
5-89
*SRE
Sets the service request enable register or queries the current setting.
5-90
*STB?
Queries the status byte register.
5-90
*TRG
Executes the same operation as when SINGLE (SHIFT+HOLD) is pressed.
5-90
*TST?
Performs a self-test and queries the result.
5-90
*WAI
Holds the subsequent command until the completion of the specified overlap
operation.
5-90
5.1 Command List
Содержание wt1600
Страница 1: ...Digital Power Meter Communication Interface IM 760101 11E 4th Edition ...
Страница 131: ...7 2 IM 760101 11E 7 2 Sample Program Image ...
Страница 138: ...Sample Program 7 9 IM 760101 11E 7 7 4 Output of Normal Measurement Data ...
Страница 142: ...Sample Program 7 13 IM 760101 11E 7 7 5 Output of Harmonic Measurement Data ...