3-18
<Toc>
<3. Programming>
IM 05E01B02-41E
●
Program Parameters (Parameters for Setting the Wait and Repeat Actions)
The parameters listed below are shown when the Start Code (STC) parameter is set to “-1.”
Located in: Main menu =
PROG
; Submenu =
PRG
Start-of-repetition
segment number
1
ⱕ
RST
ⱕ
REN
ⱕ
99
1
End-of-repetition
segment number
1
REN
RST
Parameter
Symbol
Name of Parameter
Setting Range and Description
Initial Value
1st group of wait
zones
OFF: No function
0.0 to 10.0% of PV input range span
OFF
1st group of wait
times
OFF: No function
0.01 to 99.59 (“hour, minute” or “minute, second”)
Use the TMU setup parameter to set the time unit.
OFF
User
Setting
Target Item
in CD-ROM
1.WTM
1.WZ1
2nd group of wait
times
Same as the 1st group of wait times.
2.WTM
Number of repetitions
0 to 999: The controller repeats the segment specified by the RST
and REN parameters as many times as defined by this parameter.
CONT: The controller indefinitely repeats the segment specified
by the RST and REN parameters.
0
RCY
2nd group of wait
zones
Same as the 1st group of wait zones.
2.WZ1
3rd group of wait
times
Same as the 1st group of wait times.
3.WTM
3rd group of wait
zones
Same as the 1st group of wait zones.
3.WZ1
4th group of wait
times
Same as the 1st group of wait times.
4.WTM
4th group of wait
zones
Same as the 1st group of wait zones.
4.WZ1
5th group of wait
times
Same as the 1st group of wait times.
5.WTM
5th group of wait
zones
Same as the 1st group of wait zones.
5.WZ1
Ref.5.2(4)
Ref.5.2(6)
●
Program Parameters (Parameters for Setting the Final Target Setpoints
and Segment Times)
Located in: Main menu =
PROG
; Submenu =
PRG
Final target setpoint
The final target setpoint of each segment.
HHHHH
Time-set segment time
Time setpoint: - (unregistered)
0.00 to 99.59 (“hour, minute” or “minute, second”)
Without a time setpoint, it is not possible to create programs.
TIME
TSP1
Ramp-set segment time
For ramp segments (ramp setpoint): - (unregistered), 0.0 to 100.0% of PV input
range span per hour or minute
For soak segments: 0.00 to 99.59 (“hour, minute” or “minute, second”)
Without a time setpoint or a ramp grade setpoint, it is not possible to create programs.
TM.RT
Segment PID group
number
This parameter is shown for segment PID parameters when
the setup parameter “ZON” is set to 0.
This parameter is factory-set so as not to appear.
1 to 8
Note: The controller uses the 1st group of PID for operation
when segment PID group number (PID) is larger than the
PID group number (setup parameter GRP).
1
PID
Parameter
Symbol
Name of Parameter
Setting Range and Description
Initial Value
User
Setting
Target Item
in CD-ROM
Ref.5.1(1)
Ref.5.1(2)