1-8
IM 701830-01E
A Delay B trigger (Enhanced Trigger)
→
Page 6-12.
A trigger is activated the 1st time condition B becomes true after condition A has become true
and a preset time has elapsed.
L
H L
L
H
H
H
H
H
L
L
L
H
CH1
CH2
CH1
CH2
Trigger
L H
H
L
L
Pattern A is true Pattern B is true
2
µ
s
When pattern A : CH1 = L, CH2 = L, Enter, When pattern B : CH1 = H, CH2 =H, Enter, Delay = 2
µ
s
Edge on A (Enhanced Trigger)
→
Page 6-14.
A trigger is activated when an OR trigger occurs while condition A is true.
L
H
L
L
L
H
H
H
H
H
L
L
L
L
L
H
L
L
H
H
L
L
H
CH1
CH2
CH3
CH4
CH1
CH2
CH3
CH4
When pattern A : CH1 = L, CH2 = L, CH3 = H, CH4 = L, True, Edge OR : CH6
↑
Trigger
CH6
CH6
OR trigger (Enhanced Trigger)
→
Page 6-16.
A trigger is activated when either of the selected edge triggers occurs. A trigger can be
activated by either the rising edge of CH1 or CH2.
When CH1 =
↑
, CH2 =
↑
Trigger
CH1
Trigger
Trigger
CH2