Web Statistics
73
Item
Description
that is numbered RPN3 and the signal value is -76dBm.
Note
: RSSI refreshes automatically every 20 seconds.
Interference
Number of interferences detected by base.
Fre/Slot
Fre
: frequency band where the base on a higher sync level is located.
Slot
: slot where the base on a higher sync level is located.
For example, "8/6 (Good)" indicates that the frequency band of the base on a higher sync
level is 8, the slot is 6, and the synchronization with the base is Good.
Note
: The synchronization with the base on a higher sync level includes
Good
,
Normal
,
Weak
,
Unknown
, and "
-
", where
Unknown
is displayed when the information is not updated,
and "
-
" is displayed when the base is offline.
Signal Num
The number of signals that is greater or equal to -88dbm (RSSI > =-0x48) detected by base.
Network Drop
The number of network disconnections.
Start Time
The latest startup time of the base.
Note
: It will not be reset even if you manually clear the statistical data.
Due to the different base statuses, the following items are specially explained:
l
Async
、
Network Drop
: Corresponding values are displayed for any base status.
l
Signal Num
、
Start Time
: A value is displayed only when the base status is
Active
or
Active and synced
, and
"—" is displayed for other base statuses.
l
RSSI
、
Fre/Slot
: A value is displayed only when the base status is
Active and synced
, and "—" is displayed for
other base statuses.
l
For the base with sync level 1, the following items always display "-":
RSSI
,
Async
, and
Fre/Slot
.
Cluster Graph Statistics
The tree map is described as follows:
(1) Cables
Different cables are used between the bases to indicate the synchronized base signal.
l
Solid blue line
(
): -85dBm <= RSSI <= -28dBm
l
Red dotted line
(
): -99dBm < RSSI <= -86dBm
l
Gray dotted line
(
): No data available
Note
: When the base status is not
Active and synced
, the base does not display the synchronized RSSI value. Both are
connected with a gray dotted line.
If the previous base on a higher sync level cannot be found (such as the base was deleted), there is no connection line, it is
displayed individually and placed under the base with sync level 1.
(2) Circles
Different circles are used to indicate different base status.
Содержание W80
Страница 1: ......
Страница 3: ...3 Administrator s Guide for W80 DECT IP Multi Cell System ...
Страница 33: ...Administrator s Guide for W80 DECT IP Multi Cell System 30 ...
Страница 259: ...Administrator s Guide for W80 DECT IP Multi Cell System 256 W80DM Menu Structure Overview ...
Страница 260: ...Appendix 257 W80B Menu Structure Overview ...