17
O R I G I N A L I N S T R U C T I O N S
EN
Portable residual current device (PRCD) test
The product is equipped with an automatic portable residual current device located on the power cord near the plug (VI), which is
used as a protection when working with electrical tools that come into contact with water when operated. Every time before starting
work, test its operation. Check that the tool power switch is in the o
ff
position – O, and the disc does not come into contact with
any object. Plug the power cord plug into the mains socket. Press the button marked “TEST” on the PRCD housing; the indicator
light on the PRCD will go o
ff
. Press the button marked “RESET” and then turn on the product by pressing the power switch; the
indicator light should illuminate.
If the indicator light does not go o
ff
after pressing the button marked “TEST” or goes o
ff
after turning on the product, immediately
stop the product operation, disconnect the power cord plug from the mains socket and hand the product over to the authorised
service centre of the manufacturer.
Caution! It is forbidden to use the product with a damaged portable residual current device.
Speed control (VII)
The polisher has a speed control dial located above the power switch. The speed can be adjusted smoothly within the range
speci
fi
ed in the technical data table. The higher the number shown on the control dial, the higher the speed.
Removing the polishing disc
Turn o
ff
the polisher and unplug the polisher power cord plug from the mains socket.
Push in the spindle lock and unscrew the polishing disc from the spindle.
OPERATING THE POLISHER
Unplug the power cord plug of the tool from the mains socket!
Before using the tool, check that the housing body and power cord with the plug are not damaged. If any damage is visible, it is
forbidden to connect the device to the mains!
Check if the polishing pad or disc are damaged. If any cracks, scratches or other damage are visible, replace the pad or disc with
a new one free of these defects.
It is forbidden to work with defective polishing pads and discs!
Select the right type of polishing pad for the job.
Wear eye protection, hearing protection, and work gloves.
Check that the power switch is in the o
ff
position – O. Then insert the power cord plug of the device into the mains socket.
Adopt the right posture which will guarantee maintaining balance (VIII), turn on the polisher by setting the power switch to the on
position – I. The power switch can be locked in the on position – I. The tool is stopped by setting the power switch to the rear posi-
tion. The spring will set the power switch to the o
ff
position – O. Start working by gently applying the side surface of the pad to the
workpiece. Do not exert too much pressure on the workpiece during operation. Move the tool to and fro with smooth movements.
Observe the e
ff
ects and adjust the speed and pressure of the polishing disc.
Do not overload the polisher – the temperature of the external surfaces must never exceed 60
O
C.
After
fi
nishing work, turn o
ff
the device by setting the power switch to the o
ff
position – O. After releasing the power switch, the disc
will keep spinning for some time. Do not put the polisher away until the disc has come to a complete standstill. Close the water
supply, unplug the power cord plug from the mains socket and proceed with maintenance.
MAINTENANCE, STORAGE AND TRANSPORT
CAUTION! Before carrying out any adjustment, servicing or maintenance work, unplug the tool’s plug from the mains socket.
Ensure that the water supply to the device is closed.
Disconnect the device from the water supply. To do this, press and hold the end of the water connector and slide the hose o
ff
the
connector. Remove water from the device’s system. To do this, open the valve and point the water inlet downwards, the water
should
fl
ow by gravity out of the tool system. Having
fi
nished working, inspect the power tool for damage by visually inspecting
the exterior and the body and the handles. Check the power cord, the plug, the action of the electric power switch, the ventilation
openings for clogging, the motor brushes for sparking, the noise of the bearings and the drive gear, and how the power tool starts
and runs. During the warranty period, the user is not allowed to disassemble the power tool or replace any components or parts,
as this will void the warranty rights. Any irregularities found during the inspection or the operation signal the need for repair to be
done at the service centre. Having
fi
nished your work, clean the housing, the ventilation openings, switches, additional handles
and guards with compressed air jet at 0.3 MPa maximum, a brush or a dry cloth. Do not use any chemicals or cleaning agents.
Clean the tools and handles with a clean and dry cloth.
The product should be stored thoroughly cleaned and dried. Store the product indoors.
Secure against unauthorized access. Adequate ventilation must be provided in the storage area to prevent condensation. The
place of storage should protect the product from weather conditions.
The product should be transported in unit packaging or other hard packaging providing protection against shocks. Protect the
product from moisture during transport.
Содержание YT-82161
Страница 25: ...25 RU residual current device RCD...
Страница 26: ...26 RU...
Страница 27: ...27 RU 10...
Страница 28: ...28 RU II III 1 IV V...
Страница 29: ...29 RU PRCD VI TEST PRCD PRCD RESET TEST VII O VIII I I O 60 C O...
Страница 30: ...30 RU 0 3...
Страница 32: ...32 UA residual current device RCD...
Страница 33: ...33 UA...
Страница 34: ...34 UA 10...
Страница 35: ...35 UA II III 1 IV V PRCD VI TEST PRCD PRCD RESET...
Страница 36: ...36 UA TEST VII O VIII I I O 60O C O 0 3...
Страница 98: ...98 GR RCD RCD...
Страница 99: ...99 GR...
Страница 100: ...100 GR 10 mm...
Страница 101: ...101 GR II III 1 IV V PRCD VI O TEST...
Страница 102: ...102 GR PRCD PRCD RESET TEST VII VIII I I O 60 o C O 0 3 MPa...
Страница 104: ...104 BG RCD RCD...
Страница 105: ...105 BG...
Страница 106: ...106 BG 10 mm II...
Страница 107: ...107 BG III 1 IV V PRCD VI TEST PRCD PRCD RESET TEST...
Страница 108: ...108 BG VII VIII I I O 60o C 0 3 MPa...
Страница 120: ...120 AR YT M LpA KpA LwA KwA ah p K IP...
Страница 121: ...121 AR RCD DCR...
Страница 122: ...122 AR II III IV V PRCD VI PRCD PRCD TEST RESET TEST VII...
Страница 123: ...123 AR O I I VIII O O...
Страница 125: ...I N S T R U K C J A O R Y G I N A L N A 125...