Command Reference
Condition Select
from:
Condition Code
> 1
< 2
Serial
1 U
Value
Specify the value against which the variable
must be compared, using decimal format.
Serial
4 V
Notes
Specify which output must be set to ON by setting parameter
Pn2D2.0 as follows:
0: Fast output setting disabled (default).
1: Output 1 (CN1-25,26)
2: Output 2 (CN1-27,28)
3: Output 3 (CN1-29,30)
After configuring Pn2D2.0, the assigned output will function as a
Coincidence output until the FAST_OUTPUT_SETTING command
is issued. A Coincidence output signal is produced when the
position error is smaller than defined by Pn500 and the motion
command has ended.
After the FAST_OUTPUT_SETTING command is issued, the
output selected by Pn2D2.0 will function as specified by the
FAST_OUTPUT_SETTING command.
After issuing a FAST_OUTPUT_SETTING command, it is not
possible to restore the output to function as a Coincidence
output. To set the output to function as a Coincidence output,
use a FAST_OUTPUT_SETTING command, with <variable> set to
Distance_from_target.
108
XtraWare User Manual