Error Messages
Error message
Will servo
turn
Will program
Error
Code
Will motor
stop motion?
from
Description
flow stop?
off?
XtraWare
With
Fault
Mngr
Code
W/O
Fault
Mngr
Code
With
Fault
Mngr
Code
W/O
Fault
Mngr
With
Fault
Mngr
Code
W/O
Fault
Mngr
Code
Code
99 A.08:
Wrong
value of
parameter
Pn199 or Pn280
Wrong value of
parameter Pn199
or Pn280.
Yes Yes Yes Yes Yes
68
A.10: Over
current or Heat
Sink
Overheated
An over current
flowed through
the IGBT. Heat
sink of the servo
amplifier was
overheated.
Yes Yes Yes Yes Yes
69
A.30:
Regeneration
Error Detected
Regeneration
Error Detected.
Regeneration
circuit, or
resistor, is faulty.
Yes Yes Yes Yes Yes
70 A.32:
Regenerative
Overload
Regenerative
energy exceeds
regenerative
resistor capacity.
Yes Yes Yes Yes Yes
100 A.33:
Wrong
Input Power.
Amplifier is in
AC input mode
(Pn001.2=0),
but has DC
input or vice
versa
Wrong Input
Power. Amplifier
is in AC
input mode
(Pn001.2=0), but
has DC input or
vice versa
Yes Yes Yes Yes Yes
71 A.40:
Over voltage
Main circuit DC
voltage is
excessively high.
Yes Yes Yes Yes Yes
72 A.41:
Under voltage
Main circuit DC
voltage is
excessively low.
Yes Yes Yes Yes Yes
73 A.51:
Over speed
Rotational speed
of the motor is
excessively high.
Yes Yes Yes Yes Yes
74 A.71:
Overload:High
Load
The motor was
operating for
several seconds
at a torque
largely exceeding
rated torque.
Yes Yes Yes Yes Yes
XtraWare User Manual
201
Содержание XTRAWARE - V3.0
Страница 2: ......
Страница 4: ......
Страница 12: ......
Страница 79: ...Operating the XtraDrive Using XtraWare Table 14 Sample ECAM Table XtraWare User Manual 69 ...
Страница 202: ......
Страница 220: ......
Страница 258: ...List of Operation Codes 248 XtraWare User Manual versions use STOP_EX ...