Operating the XtraDrive Using XtraWare
The program will execute differently depending on whether or not In 1
changes during motion, as explained below.
Case 1: In 1 does not change during motion
Figure 56: Interrupt Example – Output Chart Case 1
From the chart:
♦
The motor started moving after In 1 became true.
♦
As the motor target speed reached 400, output 1 was set to ON as
interrupt 0 was invoked as a result of its condition
(Target_velocity>=400) being met.
♦
The program returned to the MOVE_D command.
♦
Once the motor completed its motion, the output was set to OFF.