Command Reference
RUN
Table explanation
Group
Program Flow Control
Syntax
RUN <n>
Op. Code
78
Modes
Immediate, Sequential
Description
Runs a program or a subroutine
from the specified label.
Syntax
Arguments
n
The label number.
Serial
1 U
See Also
LABEL, CALL
Parameter Pn2CC
SET_OUTPUT
Table explanation
Group
Output
Syntax
SET_OUTPUT <n> <switch>
op. Code
79
Modes
Program, Immediate, Sequential
Description
Sets a digital output pin to ON or OFF.
There are three logical outputs that can be set corresponding to
the three output pins on the XtraDrive.
Syntax
Arguments
n
Digital output number, set according to the table
below.
Output
number
Digital Output
1 Out_1
(CN1-25,26)
2 Out_2
(CN1-27,28)
3 Out_3
(CN1-29,30)
Serial
2 U V
148
XtraWare User Manual
Содержание XTRAWARE - V3.0
Страница 2: ......
Страница 4: ......
Страница 12: ......
Страница 79: ...Operating the XtraDrive Using XtraWare Table 14 Sample ECAM Table XtraWare User Manual 69 ...
Страница 202: ......
Страница 220: ......
Страница 258: ...List of Operation Codes 248 XtraWare User Manual versions use STOP_EX ...