Serial Interface Protocol
To use the short format master message, M (mode) must be set for the
short format, according to the following table.
Mode Code
Broadcast Message
0x0
Polling Message
0x1
Immediate Mode
0x2
Sequential Mode
0x3
Program Mode
0x4
In this format, the V1 and V2 (Variable indicators) bytes are omitted, as the
arguments can only be specified by numerical values.
For an explanation of each component of the short format master message,
refer to section
6.2.2, Master Message.
Note:
The short format is the same format as was used in previous
versions of XtraWare, in which the specification of arguments
was limited to numerical values.
6.2.3.
Response Message
All master messages, except broadcast messages, are responded to by an
XtraDrive response message.
Format:
N A m Id1
Id2
Answer S1 S2 CR
Where:
Description:
XtraDrive message start symbol. Constant value.
N
Range:
N
Description:
Axis address. The response message holds the same axis
address as the original message.
A
Range:
0x0 – 0xF
Description:
Response type.
M
Range:
0: Acknowledge (without Fault)
1: Acknowledge (with Fault)
2: Response for data request command
3: Acknowledge with watch variables field
5: Program upload
XtraWare User Manual
183