Parameter Reference
8.2.
Table 20: Application Setting
Parameters
Table 20: Application Setting Parameters
ID
Need
Re-
start
Description
Short
Descrip.
Default
Val.
Min
Max
Unit
Hex
No.
N
eed
Pass
word
Pn2F0
Yes
Serial Protocol Type. Cycle
power On/Off for changes
to take effect.
Pn2F0.0:
0 - N-Protocol
1 - CompoWay/F
Pn2F0.1: Reserved
Pn2F0.2: Reserved
Pn2F0.3: Reserved
Serial
Protocol
Switch
0 0 1 Yes
No
Pn2F1
Yes
CompoWay / F Setting.
Pn2F1.0: Node Number
(x10^0)
Pn2F1.1: Node Number
(x10^1)
Pn2F1.2: Baud Rate
0,1,2 - 9600
3 -1200
4 - 2400
5 - 4800
6 - 9600
7 - 19200
8 - 38400
9 - 57600
CompoW
ay/F
Setting
1 0
2457
Yes
No
Pn2A0
Yes
Rotation base (Low).
Rotation
base
(Low)
0xFFFF 0
0xFF
FF
User No No
Pn2A1
Yes
Rotation base (High).
Rotation
base
(High)
0x7FFF 0
0x7F
FF
User No No
Pn2C6 Yes Communication
Switch.
Pn2C6.0: Checksum
0 - Do not use
checksum
1 - Use checksum
Pn2C6.1: Communication
definitions
0 – Default comm
setting (1 Start, 7 data, 1
stop, Even-parity)
1 - Communication with
Legend (1 start, No parity,
8 data, 1 stop)
Pn2C6.2: Reserved
Pn2C6.3: Reserved
Commun
ic-ation
Switch
1 0x00
00
0x00
11
Yes
No
218
XtraWare User Manual
Содержание XTRAWARE - V3.0
Страница 2: ......
Страница 4: ......
Страница 12: ......
Страница 79: ...Operating the XtraDrive Using XtraWare Table 14 Sample ECAM Table XtraWare User Manual 69 ...
Страница 202: ......
Страница 220: ......
Страница 258: ...List of Operation Codes 248 XtraWare User Manual versions use STOP_EX ...