Command Reference
Example
MOVE 300000 -1
FAST_OUTPUT_SETTING Position_actual_value > 100000
WAIT_VAR Position_actual_value > 100000
FAST_OUTPUT_SETTING Position_actual_value < 250000
WAIT_VAR Position_actual_value > 250000
FAST_OUTPUT_SETTING Coincidence < 200
Example
Explanation
After motion has started, a quick output is set, conditional on
Position_actual_value exceeding 100000. Output 1 is set ON as
soon as this condition is met. The fast output condition is then
changed so that Output 1 will remain on until position 250000 is
reached. Once this position is reached, Output 1 is turned off.
The fast output condition is then changed again so that Output 1
will be turned on once Distance_from_target is lower than 200.
After the motion has been completed to within the specified
position error window of 200, Output 1 is set ON again.
See Also
Parameters Pn2D2.0, Pn500