Command Reference
TORQUE_ANALOG
Table explanation
Group
Motion
Syntax
TORQUE_ANALOG
Op. Code
103
Modes
Program, Sequential
Motion
Mode
Analog Torque
Description
Enables use of an analog signal as an input of required motor
torque.
The torque generated by the driver is proportional to the voltage
that the potentiometer creates.
Parameter Pn400 determines the voltage level (in 0.01V) that is
equivalent to the motor rated torque: the higher the voltage, the
greater the torque.
Torque calculation:
[Motor Rated Torque] x [Input Voltage (0.01V)] / Pn400 =
[Generated Torque].
For example, if the rated torque is 500 [Nm], Pn400 is set to 60
(6V) and the voltage generated is 3V, the torque will be 250[Nm].
The rate of change of torque is specified by the parameter Pn2C1.
See Also
SPEED_ANALOG
Variable: Analog torque
Parameter: Pn2C1, Pn400
XtraWare User Manual
163