VS-616PS5 Programming Manual
73
• Current/Torque Limit (setting: “30”)
Closes during torque limit.
• Speed Limit (setting: “31”)
Closes when the Speed Limit Level as determined by parameter setting
(D5-03)
is
reached during torque control. The speed limit is set by
D5-04
or the analog input
.
• During Run 2 (setting: “37”)
Closes during running (does
not
close during baseblock, injection braking, or initial
excitation).
Section H: Control Circuit Terminal Parameters
H2 Digital Outputs