C3
Voltage Limit Control
This parameter sets the voltage limit control.
C3-05 Voltage Limit Control Selection
A
Set Value
Description
0
•
Voltage limitation control is not performed
(fac-
tory default).
1
•
Voltage limitation control is performed limits the
output voltage to 230 (460) by reducing the d-axis
current level.
Section C: Tuning Parameters