User Parameter Tables
4
-
29
4
Multi-function Contact Outputs: H2
Multi-function Contact Output Functions
20 to 2F
External fault
Input mode: NO contact/NC contact, Detection mode: Normal/during operation
Yes
Yes
Yes
-
80
Nominal Speed Reference
Yes
Yes
Yes
-
81
Intermediate Speed Reference
Yes
No
No
-
82
Releveling Speed Reference
Yes
Yes
Yes
-
83
Leveling Speed Reference
Yes
Yes
Yes
-
84
Inspection Run Command
Yes
Yes
Yes
-
85
Battery Operation Command
Yes
Yes
Yes
-
86
Output Contactor Answer Back Signal
Yes
Yes
Yes
-
87
High Speed Limit Switch (UP)
Yes
Yes
Yes
-
88
High Speed Limit Switch (Down)
Yes
Yes
Yes
-
Param-
eter
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
MEMO-
BUS
Register
Page
V/f
Open
Loop
Vector
Closed
Loop
Vector
Display
H2-01
Terminal
M1-M2 func-
tion selection Multi-function contact
output 1
0 to 43
40
No
A
A
A
40BH
-
Term
M1-M2 Sel
H2-02
Terminal
M3-M4 func-
tion selection Multi-function contact
output 2
0 to 43
41
No
A
A
A
40CH
-
Term
M3-M4 Sel
H2-03
Terminal
M5-M6 func-
tion selection Multi-function contact
output 3
0 to 43
6
No
A
A
A
40DH
-
Term
M5-M6 Sel
Set-
ting
Value
Function
Control Methods
Page
V/f
Open
loop
Vector
Closed
Loop
Vector
0
During run (ON: run command is ON or voltage is being output)
Yes
Yes
Yes
5-47
1
Zero-speed
Yes
Yes
Yes
5-47
2
f
ref
/f
out
agree 1 (detection width L4-02 is used.)
Yes
Yes
Yes
5-24
3
f
ref
/f
set
agree 1 (ON: Output frequency = ±L4-01, with detection width L4-02 used
and during frequency agree)
Yes
Yes
Yes
5-24
4
Frequency detection 1 (ON: +L4-01
≥
output frequency
≥
-L4-01, with detection
width L4-02 used)
Yes
Yes
Yes
5-24
5
Frequency detection 2 (ON: Output frequency
≥
+L4-01 or output frequency
≤
-L4-
01, with detection width L4-02 used)
Yes
Yes
Yes
5-24
6
Inverter operation ready
READY: After initialization or no faults
Yes
Yes
Yes
5-47
7
During DC bus undervoltage (UV) detection
Yes
Yes
Yes
5-47
8
During baseblock (NO contact, ON: during baseblock)
Yes
Yes
Yes
5-47
9
Frequency reference source selection (ON: Frequency reference from Operator)
Yes
Yes
Yes
5-47
Setting
Value
Function
Control Methods
Page
V/f
Open
Loop
Vector
Closed
Loop
Vector
http://nicontrols.com