5
-66
Battery selection
Use the following battery
Note Main bus voltage during battery operation is decided based on the 10% of motor base speed.
Voltage drop must be less than 5% under the following load condition.
Current of control power : 50W/ control voltage
Current of main power : (motor rated power x speed during battery operation x 200%) /
(battery voltage x 60%( motor efficiency ) x motor base speed)
200V Class
400V Class
Main bus voltage
more than 48V
more than 96V
Control voltage
200V
400V