Wiring Main Circuit Terminals
2-
9
2
Table 2.3 Lug Sizes (JIS C2805) (200 V Class and 400 V Class)
Wire Thickness (mm
2
)
Terminal Screws
Size
0.5
M3.5
1.25 / 3.5
M4
1.25 / 4
0.75
M3.5
1.25 / 3.5
M4
1.25 / 4
1.25
M3.5
1.25 / 3.5
M4
1.25 / 4
2
M3.5
2 / 3.5
M4
2 / 4
M5
2 / 5
M6
2 / 6
M8
2 / 8
3.5/5.5
M4
5.5 / 4
M5
5.5 / 5
M6
5.5 / 6
M8
5.5 / 8
8
M5
8 / 5
M6
8 / 6
M8
8 / 8
14
M6
14 / 6
M8
14 / 8
22
M6
22 / 6
M8
22 / 8
30/38
M8
38 / 8
50/60
M8
60 / 8
M10
60 / 10
80
M10
80 / 10
100
100 / 10
100
M12
100 / 12
150
150 / 12
200
200 / 12
325
M12 x 2
325 / 12
M16
325 / 16
IMPORTANT
Determine the wire size for the main circuit so that line voltage drop is within 2% of the rated voltage. Line
voltage drop is calculated as follows:
Line voltage drop (V) =
x wire resistance (W/km) x wire length (m) x current (A) x 10
-3
3