Protective Functions
5-
35
5
Related Parameters
Multi-function Output (H2-01 to H2-03)
L6-01 and L6-04 Set Values and Operator Display (JVOP-160 only)
The relationship between alarms displayed on the digital operator when overtorque or undertorque is detected,
and the set values in L6-01 and L6-04, is shown in the following table.
Parameter
No.
Name
Factory
Setting
Change
during
Operation
Control Methods
V/f
Open
Loop
Vector
Closed
Loop
Vector
L6-01
Torque detection selection 1
2
No
A
A
A
L6-02
Torque detection level 1
150%
No
A
A
A
L6-03
Torque detection time 1
10.0 s
No
A
A
A
L6-04
Torque detection selection 2
0
No
A
A
A
L6-05
Torque detection level 2
150%
No
A
A
A
L6-06
Torque detection time 2
0.1 s
No
A
A
A
Set
Value
Function
Control Methods
V/f
Open
Loop
Vector
Close
d Loop
Vector
B
Overtorque/undertorque detection 1 NO
(NO contact: Overtorque detection and undertorque detection enabled when contact is ON)
Yes
Yes
Yes
17
Overtorque/undertorque detection 1 NC
(NC contact: Overtorque detection and undertorque detection enabled when contact is OFF)
Yes
Yes
Yes
18
Overtorque/undertorque detection 2 NO
(NO contact: Overtorque detection and undertorque detection enabled when contact is ON)
Yes
Yes
Yes
19
Overtorque/undertorque detection 2 NC
(NC contact: Overtorque detection and undertorque detection enabled when contact is OFF)
Yes
Yes
Yes
Set
Value
Function
Operator Display
Overtorque/
Undertorque
Detection 1
Overtorque/
Undertorque
Detection 2
0
Overtorque/undertorque detection disabled.
–
–
1
Overtorque detection only with speed agree; operation continues (warning is output).
OL3 flashes
OL4 flashes
2
Overtorque detected continuously during operation; operation continues (warning is
output).
OL3 flashes
OL4 flashes
3
Overtorque detection only with speed agree; output is stopped upon detection.
OL3 lights up
OL4 lights up
4
Overtorque detected continuously during operation; output is stopped upon detection.
OL3 lights up
OL4 lights up
5
Undertorque detection only with speed agree; operation continues (warning is output).
UL3 flashes
UL4 flashes
6
Undertorque detected continuously during operation; operation continues (warning is
output).
UL3 flashes
UL4 flashes
7
Undertorque detection only with speed matching; output is stopped upon detection.
UL3 lights up
UL4 lights up
8
Undertorque detected continuously during operation; output is stopped upon detection.
UL3 lights up
UL4 lights up