Setting User Constants
4.2.3 User Constant Access Levels
4 - 10
A
EXAMPLE
"
Setting a User Constant in the Advanced Access Level
The group level will be displayed when the DATA/ENTER Key is pressed at the programming mode dis-
play.
Use the following procedure to set a constant.
Step
Key Sequence
Digital Operator Display
Remarks
1
MENU
G5
:
Main Menu
:
Operation
2
Press twice.
G5
:
Main Menu
:
Programming
3
DATA
ENTER
Group b
Application
4
Group C
Tuning
5
DATA
ENTER
Function C1
Accel/Decel
Changed to constant reading (function)
level.
6
DATA
ENTER
Accel Time 1
C1
−
01 = 10.0 Sec
7
DATA
ENTER
Accel Time 1
0010.0 Sec
Selects the user constant so that the
leading 0 blinks. The blinking digit
can be changed.
8
RESET
Press twice.
Accel Time 1
0010.0 Sec
Blinking digit moves 2 places to the
right and the “1” blinks.
9
Accel Time 1
0020.0 Sec
Changes 1 to 2.
10
DATA
ENTER
Entry Accepted
Writes-in the new setting, 20.0 s.
Accel Time 1
C1
−
01 = 20.0 Sec
After a few seconds, the Operator dis-
play is as shown on the left.
11
ESC
Function C1
Accel/Decel
The constant setting in Advanced level (acceleration time change from 10.0 to 20.0 s) has been completed.