User Constant Initial Value: o2-03
User
Change
during
Setting
Factory
Valid Access Levels
User
Constant
Number
Name
g
during
Opera-
tion
Setting
Range
Unit Factory
Setting
V/f
Control
V/f with
PG
Open
Loop
Vector
Flux
Vector
o2-03
User constant initial
value
×
0, 1, 2
−
0
B
B
B
B
D
This constant is used to record or clear the user constant defaults.
D
Once the user defaults have been recorded, constant A1-03 can be used to initialize the Inverter
constants to these defaults.
D
If the “Out Of Memory Max Param Change” display appears on the digital operator when registering
the user constants after the setting has been changed, do not immediately change or register the settings
because pre-registered user settings may be cleared.
D
Settings
Setting
Function
0
No change. (Retain current settings.)
1
Record user defaults. (Record the current constant settings as user defaults.)
2
Clear user defaults. (Clear the recorded user defaults.)
D
The Digital Operation display will return to 0 after the settings have been made.
kVA Selection: o2-04
User
Change
during
Setting
Factory
Valid Access Levels
User
Constant
Number
Name
g
during
Opera-
tion
Setting
Range
Unit Factory
Setting
V/f
Control
V/f with
PG
Open
Loop
Vector
Flux
Vector
o2-04
kVA selection
×
0 to FF
−
0
B
B
B
B
D
The setting range and factory setting depend on the Inverter capacity. The settings shown in the table
are for a 200 V class, 0.4 kW Inverter. (See page 8 - 47.)
D
Do not change this constant setting; it is used by the manufacturer to identify the Inverter model.
D
Use this setting only the the control PC board has been replaced.
Frequency Reference Setting Method Selection: o2-05
User
Change
during
Setting
Factory
Valid Access Levels
User
Constant
Number
Name
g
during
Opera-
tion
Setting
Range
Unit Factory
Setting
V/f
Control
V/f with
PG
Open
Loop
Vector
Flux
Vector
o2-05
Frequency reference
setting method selec-
tion
×
0, 1
−
0
A
A
A
A
D
This constant determines whether it is necessary to press the Enter Key when changing the frequency
reference with the Digital Operator’s frequency reference monitor; it cannot be changed during opera-
tion.
D
When o2-05 is set to 1 (DATA/ENTER Key input not required.), the frequency reference changes si-
multaneously with the Digital Operator’s value.
D
Settings
Setting
Function
0
DATA/ENTER Key input required.
1
DATA/ENTER Key input not required.
Operation Selection when Digital Operator is Disconnected: o2-06
User
Change
during
Setting
Factory
Valid Access Levels
User
Constant
Number
Name
g
during
Opera-
tion
Setting
Range
Unit Factory
Setting
V/f
Control
V/f with
PG
Open
Loop
Vector
Flux
Vector
o2-06
Operation selection
when digital opera-
tor is disconnected
×
0, 1
−
0
A
A
A
A
D
If the Digital Operator has command rights, this constant specifies whether to stop operation when the
Digital Operator is disconnected.
7