7 - 77
Constant Settings
User
Change
during
Setting
Factory
Valid Access Levels
User
Constant
Number
Name
g
during
Opera-
tion
Setting
Range
Unit Factory
Setting
V/f
Control
V/f with
PG
Open
Loop
Vector
Flux
Vector
H2-01
Multi-function input
(terminal 9-10)
×
0 to 37
−
0
B
B
B
B
H2-02
Multi-function input
(terminal 25)
×
0 to 37
−
1
B
B
B
B
H2-03
Multi-function input
(terminal 26)
×
0 to 37
−
2
B
B
B
B
D
The following table shows the settings and section references for functions that are described in more
detail in this chapter.
Function
Setting
Section
Frequency Agree 1
2
Desired Frequency Agree 1
3
Frequency Detection Settings
:
L4-01
to
L4-05
in
Frequency Detection 1
4
Frequency Detection Settings
:
L4 01
to
L4 05
in
7.5.6
Frequency Detection 2
5
Overtorque Detection 1 (NO)
B
Overtorque Detection Settings: L6-01 to L6-06
in
7.5.6
Loss of Frequency Reference
C
Timer Functions: b4 01 b4 02
in 7 5 1
Timer Function Output
12
Timer Functions: b4-01, b4-02
in 7.5.1
Frequency Agree 2
13
Desired Frequency Agree 2
14
Frequency Detection Settings
:
L4-01
to
L4-05
in
Frequency Detection 3
15
Frequency Detection Settings
:
L4 01
to
L4 05
in
7.5.6
Frequency Detection 4
16
Overtorque Detection 1 (NC)
17
Overtorque Detection 2 (NO)
18
Overtorque Detection Settings: L6-01 to L6-06
in
7.5.6
Overtorque Detection 2 (NC)
19
7.5.6
D
Refer to
Table 7.10 Multi-function Output Functions
for information on the following functions.
Function
Setting
Inverter Operation Ready
6
DC Bus Undervoltage
7
During Baseblock
8
Frequency Reference Selection
9
Run Command Selection
A
Braking Resistor Fault
D
Fault
E
Minor Fault
10
Fault Reset Command Active
11
During Reverse Run
1A
During Baseblock 2
1B
Regenerating
1D
Restart Enabled
1E
During Torque Limit (Current Limit)
30
During Speed Limit
31
7