12 Appendix
12.4.3 Monitor Modes
12-40
12.4.3 Monitor Modes
The following list shows available monitor modes.
* Available for the software version 32 or later
Parame-
ter No.
Content of Display
Unit
Un000
Actual motor speed
mm/s
Un001
Input speed reference
mm/s
Un002
Internal force reference (Value for rated force)
%
Un003
Electrical angle 1 (16-bit decimal code)
number of pulses from the
phase-U (0
°
)
Un004
Electrical angle 2 (Angle from 0 (zero) degree of phase-U)
deg
Un005
Input signal monitor
−
Un006
Output signal monitor
−
Un007
Input reference pulse speed (displayed only in position control mode)
mm/s
Un008
Error counter (amount of position error) (displayed only in position control
mode)
reference unit
Un009
Accumulated load rate (Value for the rated force as 100%: Displays effective
force in 10 s cycle.)
%
Un00A
Regenerative load rate (Value for the processable regenerative power as 100%:
Displays regenerative power consumption in 10 s cycle.)
%
Un00B
Power consumed by DB resistance
(Value for the processable power when dynamic brake is applied as 100%: Dis-
plays DB power consumption in 10 s cycle.)
%
Un00C
Input reference pulse counter (32-bit decimal code)
(displayed only in position control mode)
−
Un00D
Feedback pulse counter (32-bit decimal code)
−
Un010
∗
Motor maximum speed setting upper limit or encoder output resolution setting
upper limit
100mm/s or
Pulse/scale pitch (Pn280)
Un011
∗
Hall sensor signal monitor
−