![YASKAWA SGLFW Скачать руководство пользователя страница 430](http://html.mh-extra.com/html/yaskawa/sglfw/sglfw_user-manual_3223785430.webp)
12 Appendix
12.4.2 List of Parameters
12-32
* 1. Available for the software version 32 or later
* 2. To reduce any danger while setting up the linear servomotor, the factory settings are set to low values
(factory setting: 30%). After the servomotor has been set up, increase the settings of the parameters to the
required force. For details, refer to
9.2 Trial Operation Using SERVOPACK Internal References
.
Parameter
No.
Name
Setting Range
Unit
Factory
Setting
Setting
Validation
Reference
Section
Pn406
Emergency Stop Force
0 to 800
1%
800
Immedi-
ately
9.6.3
Pn408
Force Function Switches
−
−
0000
Immedi-
ately
−
Pn409
Notch Filter Frequency
50 to 2000
1 Hz
2000
Immedi-
ately
10.4.10
Pn40A
Notch Filter Q Value *1
50 to 400
0.01
70
Immedi-
ately
10.4.10
Pn40B
Notch Filter 2 Frequency *1
50 to 2000
1 Hz
2000
Immedi-
ately
10.4.10
Pn40C
Notch Filter 2 Q Value *1
50 to 400
0.01
70
Immedi-
ately
10.4.10
Pn480
Speed Limit during Force Control
0 to 5000
1 mm/s
5000
Immedi-
ately
9.9.4
Pn481
Polarity Detection Speed Loop Gain
1 to 2000
1 Hz
40
Immedi-
ately
9.2.3
Pn482
Polarity Detection Speed Loop Integral
Time Constant
15 to 51200
0.01 ms
3000
Immedi-
ately
9.2.3
Pn483
Forward Force Limit *2
0 to 800
1 %
30
Immedi-
ately
9.2.3
9.11.1
Pn484
Reverse Force Limit *2
0 to 800
1 %
30
Immedi-
ately
Pn500
Positioning Completed Width
0 to 250
1 reference
unit
7
Immedi-
ately
9.8.5
Pn504
NEAR Signal Width
1 to 250
1 reference
unit
7
Immedi-
ately
9.8.6
Pn505
Overflow Level
256 to 8388352
256 refer-
ence units
262144
Immedi-
ately
10.3.3
Pn506
Brake Reference - Servo OFF Delay Time
0 to 50
10 ms
0
Immedi-
ately
−
Pn508
Servo OFF - Brake Reference Waiting
Time
10 to 100
10 ms
500
Immedi-
ately
−
Pn509
Momentary Hold Time
20 to 1000
1 ms
20
Immedi-
ately
9.6.5
0
1
N/A
N/A
Uses a notch filter for force reference.
Notch Filter Selection 1
(Refer to
10.4.12
)
4th
digit
3rd
digit
2nd
digit
1st
digit
n.
0
1
Uses the notch filter 2 for force reference.
Notch Filter Selection 2
∗
1
(Refer to
10.4.12
)
Reserved (Do not change)
Reserved (Do not change)
Содержание SGLFW
Страница 270: ...9 3 9...