7 Wiring
7.4.1 Speed Control Mode
7-22
7.4 Examples of I/O Signal Connections
7.4.1 Speed Control Mode
* 1.
represents twisted-pair wires.
* 2. The time constant for the primary filter is 47
µ
s.
* 3. Enabled by the parameter setting.
* 4. Customers must purchase a 24 VDC power supply with double-shielded enclosure.
Note: The functions allocated to the input signals SI0 to SI6 and the output signals SO1 to SO3 can be
changed by using the parameters. Refer to
8.3.2 Input Circuit Signal Allocation
and
8.3.3 Output
Circuit Signal Allocation
.
SERVOPACK
PBO
PCO
/PBO
PAO
/PAO
/PCO
/V-CMP+
/V-CMP-
/TGON+
/TGON-
/S-RDY+
ALM+
ALM-
FG
10
27
28
29
30
31
32
25
(SO1)
(SI0)
(SI1)
(SI2)
(SI3)
(SI4)
(SI5)
(SI6)
(SO2)
(SO3)
26
19
33
34
35
36
20
+24 V
+24VIN
3.3 k
Ω
/S-ON
/P-CON
P-OT
N-OT
/ALM-RST
/N-CL
47
41
43
42
44
45
/P-CL
46
40
/S-RDY-
∗
4.
V-REF
SG
A / D
5
6
∗
2.
∗
1.
LPF
T-REF
SG
1
SG
9
∗
2.
LPF
ALO1
ALO2
ALO3
37
38
39
Servo ON
(Servo ON when ON)
Reverse run prohibited
(Prohibited when OFF)
Forward run prohibited
(Prohibited when OFF)
Alarm reset
(Reset when ON)
Reverse current limit
(Limit when ON)
Forward current limit
(Limit when ON)
P control
(P control when ON)
Speed reference
(
±
2 to
±
10V
/rated motor
speed)
External force
limit/Force feed
forward
(
±
1 to
±
10 V
/rated force)
∗
3.
Connect shield to
connector shell.
Connector
shell
PG dividing ratio output
Applicable line receiver
SN75175 manufactured
by Texas Instruments or
the equivalent corresponding
to MC3486
Running output
(ON when the motor speed
exceeds the settings.)
Servo ready output
(ON when ready)
Servo alarm output
(OFF for an alarm)
Photocoupler output
Max. operating voltage:
30 VDC
Max. operating current:
50 mA DC
Speed coincidence detection
(ON when speed coincides.)
Alarm code output
Max. operating voltage:
30 VDC
Max. operating current:
20 mA DC