5 Specifications and Dimensional Drawings of Serial Converter Unit
5-2
5.1 Serial Converter Unit Specifications
(1) Model: JZDP-D00
-
(2) Characteristics and Specifications
* 1. The current consumption of the linear scale and hall sensor is not included in this value.
The current consumption of linear scale and hall sensor must be taken into consideration for the cur-
rent capacity of host controller that supplies the power. The current consumption of hall sensor:
Approx. 40 mA.
* 2. Input a value within the specified range. Otherwise, incorrect position information is output, and the
device may be damaged.
* 3. The transmission is enabled 100 to 300 ms after the power turns ON.
Items
Specifications
Electrical
Characteristics
Power Supply Voltage
+5.0V
±
5%, ripple content 5% max.
Current Consumption
∗
1
120 mA Typ. 350 mA Max.
Signal Resolution
Input 2-phase sine wave: 1/256 pitch
Max. Response
Frequency
250 kHz
Analog Input Signals
∗
2
(cos, sin, Ref)
Differential input amplitude: 0.4 V to 1.2V
Input signal level: 1.5 V to 3.5V
Hall Sensor Input
Signal
CMOS level
Output Signals
∗
3
Position data, hall sensor information, and alarms
Output Method
Serial data transmission
(HDLC (High-level Data Link Control) protocol format
with Manchester codes)
Transmission Cycle
62.5
µ
s
Output Circuit
Balanced transceiver (SN75LBC176 or the equivalent)
Internal terminal resistance: 120
Ω
Mechanical
Characteristics
Approx. mass
150 g
Vibration Resistance
98 m/s
2
max. (1 to 2500 Hz) in three directions
Shock Resistance
980 m/s
2
, (11 ms) two times in three directions
Environmental
Conditions
Operating temperature
0
°
C to 55
°
C (32 to 131
°
F)
Storage temperature
-20
°
C to +80
°
C (-4 to +176
°
F)
Humidity
20 % to 90 %RH (without condensation)
Содержание SGLFW