9.6 Setting Common Basic Functions
9-31
9
9.6.2 Switching the Linear Servomotor Movement Direction
The movement direction of the linear servomotor can be switched without changing the reference pulse to the
SERVOPACK or the reference voltage polarity.
This causes the travel direction (+, -) of the shaft reverse. The output signal polarity such as encoder pulse output
and analog monitor signal from the SERVOPACK does not change.
The standard setting for “forward movement” is the linear scale counting up direction.
Parameter
Name
Reference
Forward Reference
Reverse Reference
Pn000
n.
0
Standard setting
(CCW = For-
ward)
(Factory setting)
n.
1
Reverse
Direction Mode
(CW = Reverse)
The direction of P-OT and N-OT change. For Pn000 = n.
0 (standard setting), counterclockwise is P-OT. For Pn000
= n.
1 (Reverse Direction Mode), clockwise is P-OT.
Analog monitor
Moves
in forward
direction
(CCW)
Motor movement speed
Phase B progression
Force reference
Encoder pulse divided output
PAO
PBO
Analog monitor
Phase A progression
Encoder pulse devided output
PAO
PBO
Moves
in reverse
direction
(CW)
Analog monitor
Phase B progression
Encoder pulse divided output
PAO
PBO
Moves in
reverse
direction
(CW)
Phase A progression
Analog monitor
Encoder pulse divided output
PAO
PBO
Move in
forward
direction
(CCW)