12.3 Connection to Host Controller
12-19
12
12.3.4 Example of Connection to OMRON’s Position Control Unit C500-NC221
(SERVOPACK in Speed Control Mode)
* 1. The ALM signal is output for approximately two seconds when the power is turned ON. Take this
into consideration when designing the power ON sequence. The ALM signal actuates the alarm
detection relay 1Ry to stop main circuit power supply to the SERVOPACK.
* 2. Connect the I/O cable’s shield wire to the connector shell.
* 3.
represents twisted-pair wires.
Note: Only signals applicable to OMRON’s C500-NC221 position control unit and Yaskawa’s SGDH
SERVOPACK are shown in the diagram.
42
43
3Ry
1Ry
4Ry
3Ry
19
36
35
20
1
34
33
CCWLX
STPX
ORGX
EMGX
DC GND
DC GND
CWLX
X-AG
X-OUT
OUT-1X
+24V
0V
X-B
X-C
X-A
+24V +-
EXT IN
+24V
M/D
ALM+
ALM -
V-REF(T-REF)
SG
P-OT
N-OT
4Ry
3(13)
4(14)
5(15)
6(16)
1
11
2(12)
9
8
6(22)
1(17)
15(13)
16(14)
4(20)
5(21)
7(23)
8(24)
9(25)
3(19)
5(9)
6(10)
31
32
47
40
∗
1
∗
2
/S-ON
+24VIN
∗
3
11
12
X-/B
X-/C
X-/A
0
24
V
+24V
PAO
SG
PCO
PBO
/PAO
/PCO
/PBO
0
24
V
I/O power supply
X-axis (Y-axis)
Position control unit
ON when
positioning
is cancelled.
ON when
proximity
is detected.
SGDH SERVOPACK
∗
2
Connector
shell
C500-NC221
manufactured by
OMRON
CN1
L1C
L3
L2
L1
L2C
CN2
W
V
U
Linear servomotor
Linear scale
Properly treat the ends of shielded wires.
M
PG
Serial
converter
unit