![YASKAWA SGLFW Скачать руководство пользователя страница 266](http://html.mh-extra.com/html/yaskawa/sglfw/sglfw_user-manual_3223785266.webp)
8 Digital Operator/Panel Operator
8.4.5 Allowable Maximum Motor Speed for Dividing Ratio Monitor (For the software version 32 or later)
8-34
8.4.5 Allowable Maximum Motor Speed for Dividing Ratio Monitor (For the software
version 32 or later)
This section describes the monitor display for determining the maximum speed (Pn384) for the PG Divider
(Pn281). Adjust the setting of Pn080.3 to select
the location to be monitored. This function is available for Ser-
vopack Software version 32 or later.
Step
Display after
Operation
Digital Operator
Panel Operator
Description
1
Press the DSPL/SET or MODE/SET Key to select the mon-
itor mode.
2
Press the UP or DOWN Key to select “Un010.”
3
Press the DATA/ENTER Key once or DATA/SHIFT Key
for more than one second to display the motor maximum
speed that can be set.
4
Press the DSPL/SET or MODE/SET Key to display the
maximum dividing ratio that can be set.
5
Press the DATA/ENTER Key once or DATA/SHIFT Key
for more than one second to return to the display of monitor
number.
DSPL
SET
(DSPL/SET Key)
MODE/SET
(MODE/SET Key)
DATA
ENTER
(DATA/ENTER
Key)
DATA
(DATA/SHIFT Key)
(Press at least 1 s.)
DSPL
SET
(DSPL/SET Key)
MODE/SET
(MODE/SET Key)
DATA
ENTER
(DATA/ENTER
Key)
DATA
(DATA/SHIFT Key)
(Press at least 1 s.)
Содержание SGLFW