9.10 Operating Using Speed Control with an Internally Set Speed
• Internally Set Speed Selection
This function allows speed control operation by externally selecting an input signal from among three servo-
motor speed settings made in advance with parameters in the SERVOPACK. The speed control operations
within the three settings are valid. There is no need for an external speed or pulse generator.
9.10.1 Setting Parameters
Note: The maximum speed of linear servomotor is used whenever a speed settings for the Pn380 to
Pn382 exceed the maximum speed.
SERVOPACK
41
45
46
Pn380
SPEED1
Pn381
SPEED2
Pn382
SPEED3
Internally set speed
parameters
Speed
reference
Linear
Servomotor
M
Contact inputs
/P-CON (/SPD-D)
/P-CL
(/SPD-A)
/N-CL (/SPD-B)
CN1
Parameter
Meaning
Pn000
n.
3
Control mode selection: Internally set speed control (contact reference)
Pn380
Internally set speed 1 (SPEED1)
Setting Range
Setting Unit
Factory Setting
Setting Validation
0 to 5000
1 mm/s
10
Immediately
Pn381
Internally set speed 2 (SPEED2)
Setting Range
Setting Unit
Factory Setting
Setting Validation
0 to 5000
1 mm/s
20
Immediately
Pn382
Internally set speed 3 (SPEED3)
Setting Range
Setting Unit
Factory Setting
Setting Validation
0 to 5000
1 mm/s
30
Immediately