![YASKAWA SGLFW Скачать руководство пользователя страница 381](http://html.mh-extra.com/html/yaskawa/sglfw/sglfw_user-manual_3223785381.webp)
11 Inspection, Maintenance, and Troubleshooting
11.1.4 Warning Display Table when the Application Module is Used
11-6
11.1.4 Warning Display Table when the Application Module is Used
The following special warnings will occur when the SGDH SERVOPACK and an application module are used
together. The relation between warning displays and warning code outputs is shown in Table 11.4.
Note: 1. The following types of application modules are available:
NS100 (JUSP-NS100): MECHATROLINK I/F application module
NS115 (JUSP-NS115): MECHATROLINK-II I/F application module
NS300 (JUSP-NS300): DeviceNet I/F application module
NS500 (JUSP-NS500): PROFIBUS-DP I/F application module
NS600 (JUSP-NS600): INDEXER application module
2. For troubleshooting application module alarms, refer to relevant application module manual.
Manual numbers are described in
Related Manuals
on
page v
.
3. When mounting the NS115 module, observe the following restrictions on use. If the hand-held
digital operator is connected or the communications are being sent or from S and
another device (a personal computer), the following commands can not be carried out uncondi-
tionally (command warning: A.95) and the MECHATROLINK-II commands are not success-
fully sent.
PRM_RD, PRM_WR, PPRM_WR, CONFIG, ALM_RD, ALM_CLR,
SENS_ON, ADJ, ID_RD
Table 11.4 Warning Displays and Outputs when the SERVOPACK and an Application Module Is Used Together
Warning
Display
Application Module
which Detects
Warnings
Warning Name
Meaning
Warning Code
Output
Servo
Alarm
(ALM)
Output
NS
100
NS
115
NS
300
NS
500
NS
600
ALO1 ALO2 ALO3
A.94
{
{
{
{
−
Data Setting Warning
A value outside the setting range
was set using communications.
L
L
H
L
A.95
{
{
{
{
−
Command Warning
A command not supported in the
product specifications was issued.
The command reception condi-
tions were not met.
H
L
H
L
A.96
{
{
{
−
−
Communications
Warning
A communications error occurred
(once).
L
H
H
L
A.98
−
−
{
{
−
Main Power OFF
The main power supply is not
being supplied.
L
L
L
L
A.9A
−
−
{
{
−
Not Completed within
the Set Time
Positioning was not completed
within the set time.
L
H
L
L
A.9F
−
−
−
−
{
NS600 Error
Some error occurred in the NS600.
Check the NS600 Error Display
for details.
L
L
L
L