14.1 List of Parameters
14.1.2 List of Parameters
14-30
Pn516
2
Input Signal Selections
7
0000 hex to
FFFF hex
−
8888
hex
All
After
restart
Setup
−
Pn517
2
Output Signal Selec-
tions 5
0000 hex to
0666 hex
−
0654
hex
All
After
restart
Setup
Pn518
*2
–
Safety Module-Related
Parameters
−
−
−
All
−
−
−
Pn51B
4
Motor-Load Position
Deviation Overflow
Detection Level
0 to
1,073,741,824
1 refer-
ence
unit
1000
Rotary
Immedi-
ately
Setup
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.
X
FSTP (Forced Stop Input) Signal Allocation
Reference
0
Enable drive when CN1-40 input signal is ON (closed).
1
Enable drive when CN1-41 input signal is ON (closed).
2
Enable drive when CN1-42 input signal is ON (closed).
3
Enable drive when CN1-43 input signal is ON (closed).
4
Enable drive when CN1-44 input signal is ON (closed).
5
Enable drive when CN1-45 input signal is ON (closed).
6
Enable drive when CN1-46 input signal is ON (closed).
7
Set the signal to always prohibit drive (always force the motor to
stop).
8
Set the signal to always enable drive (always disable forcing the
motor to stop).
9
Enable drive when CN1-40 input signal is OFF (open).
A
Enable drive when CN1-41 input signal is OFF (open).
B
Enable drive when CN1-42 input signal is OFF (open).
C
Enable drive when CN1-43 input signal is OFF (open).
D
Enable drive when CN1-44 input signal is OFF (open).
E
Enable drive when CN1-45 input signal is OFF (open).
F
Enable drive when CN1-46 input signal is OFF (open).
n.
X
Reserved parameter (Do not change.)
n.
X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)
n.
X
ALO1 (Alarm Code Output) Signal Allocation
0
Disabled (the above signal output is not used).
1
Output the signal from the CN1-25 or CN1-26 output terminal.
2
Output the signal from the CN1-27 or CN1-28 output terminal.
3
Output the signal from the CN1-29 or CN1-30 output terminal.
4
Output the signal from the CN1-37 output terminal.
5
Output the signal from the CN1-38 output terminal.
6
Output the signal from the CN1-39 output terminal.
n.
X
ALO2 (Alarm Code Output) Signal Allocation
0 to 6
The allocations are the same as the ALO1 (Alarm Code Output) signal alloca-
tions.
n.
X
ALO3 (Alarm Code Output) Signal Allocation
0 to 6
The allocations are the same as the ALO1 (Alarm Code Output) signal alloca-
tions.
n.X
Reserved parameter (Do not change.)