6.6 Position Control
6.6.6 /NEAR (Near) Signal
6-38
6.6.6
/NEAR (Near) Signal
The /NEAR (Near) signal indicates when positioning completion is being approached.
The host controller receives the NEAR signal before it receives the /COIN (Positioning Comple-
tion) signal, it can start preparations for the operating sequence to use after positioning has
been completed. This allows you to reduce the time required for operation when positioning is
completed.
The NEAR signal is generally used in combination with the /COIN signal.
Note: You must allocate the /NEAR signal to use it. Use Pn510 = n.
X (/NEAR (Near) Signal Allocation) to allo-
cate the signal to a connector pin. Refer to the following section for details.
6.1.2 Output Signal Allocations
/NEAR (Near) Signal Setting
You set the condition for outputting the /NEAR (Near) signal (i.e., the near signal width) in
Pn524 (Near Signal Width). The /NEAR signal is output when the difference between the refer-
ence position and the current position (i.e., the position deviation as given by the value of the
deviation counter) is equal to or less than the setting of the near signal width (Pn524).
Note: Normally, set Pn524 to a value that is larger than the setting of Pn522 (Positioning Completed Width).
Parameter
Description
When
Enabled
Classification
Pn207
n.0
(default setting)
Output the /COIN signal when the absolute value of
the position deviation is the same or less than the
setting of Pn522 (Positioning Completed Width).
After
restart
Setup
n. 1
Output the /COIN signal when the absolute value of
the position deviation is the same or less than the
setting of Pn522 (Positioning Completed Width) and
the reference after the position reference filter is 0.
n. 2
Output the /COIN signal when the absolute value of
the position deviation is the same or less than the
setting of Pn522 (Positioning Completed Width) and
the reference input is 0.
Type
Signal
Connector Pin No.
Signal Status
Meaning
Output
/NEAR
Must be allocated.
ON (closed)
The Servomotor has reached a point
near to positioning completion.
OFF (open)
The Servomotor has not reached a
point near to positioning completion.
Pn524
Near Signal Width
Setting Range
Setting Unit
Default Setting
When Enabled
Classification
1 to 1,073,741,824
1 reference unit
1,073,741,824
Immediately
Setup
Position
Pn524
Pn522
0
Reference
Motor
s
peed
Time
Time
Time
Time
/COIN
s
ignal
/NEAR
s
ignal
Po
s
ition
deviation
S
peed
(Active when ON (clo
s
ed).)
(Active when ON (clo