6.6 Position Control
6.6.3 Reference Pulse Input Multiplication Switching
6
Application Function
s
6-35
Setting the Reference Pulse Input Multiplier (Pn218)
A timing chart for switching the reference pulse input multiplier is provided below.
Restrictions
The reference pulse input multiplier will not change during the following operations regardless
of the status of the /PSEL signal.
•
Program jogging
•
Autotuning without a reference input
Pn218
Reference Pulse Input Multiplier
Setting Range
Setting Unit
Default Setting
When Enabled
Classification
1 to 100
×
1 1
Immediately
Setup
CAUTION
If you change the reference pulse input multiplier (Pn218), perform trial operation of the Ser-
vomotor without the machine coupled to the motor shaft to confirm that no problems will
occur in operation before you couple the motor to the machine.
Position
1
n
(n = Pn218)
1
Internal
s
tatu
s
/P
S
ELA (Reference Pul
s
e
Input Multiplication
S
witching Output)
S
witch
/P
S
EL (Reference Pul
s
e
Input Multiplication
S
witch)
S
ignal
Enabled
Di
s
abled
Enabled
Di
s
abled
4 m
s
max.
4 m
s
max.