14.1 List of Parameters
14.1.2 List of Parameters
14-24
Pn50C
2
Input Signal Selections
3
0000 hex to
FFFF hex
−
8888
hex
All
After
restart
Setup
−
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.
X
/SPD-D (Motor Direction) Signal Allocation
Reference
0
Active when CN1-40 input signal is ON (closed).
1
Active when CN1-41 input signal is ON (closed).
2
Active when CN1-42 input signal is ON (closed).
3
Active when CN1-43 input signal is ON (closed).
4
Active when CN1-44 input signal is ON (closed).
5
Active when CN1-45 input signal is ON (closed).
6
Active when CN1-46 input signal is ON (closed).
7
The signal is always active.
8
The signal is always inactive.
9
Active when CN1-40 input signal is OFF (open).
A
Active when CN1-41 input signal is OFF (open).
B
Active when CN1-42 input signal is OFF (open).
C
Active when CN1-43 input signal is OFF (open).
D
Active when CN1-44 input signal is OFF (open).
E
Active when CN1-45 input signal is OFF (open).
F
Active when CN1-46 input signal is OFF (open).
n.
X
/SPD-A (Internal Set Speed Selection Input) Signal Allocation
Reference
0 to F
The allocations are the same as the /SPD-D (Motor Direction) sig-
nal allocations.
n.
X
/SPD-B (Internal Set Speed Selection Input) Signal Allocation
Reference
0 to F
The allocations are the same as the /SPD-D (Motor Direction) sig-
nal allocations.
n.X
/C-SEL (Control Selection Input) Signal Allocation
Reference
0 to F
The allocations are the same as the /SPD-D (Motor Direction) sig-
nal allocations.