14.1 List of Parameters
14.1.2 List of Parameters
14-12
Pn10D
2
Mode Switching Level
for Speed Reference
0 to 10,000
1 min
-1
0
Rotary
Immedi-
ately
Tuning
Pn10E
2
Mode Switching Level
for Acceleration
0 to 30,000
1 min
-1
/s
0
Rotary
Immedi-
ately
Tuning
Pn10F
2
Mode Switching Level
for Position Deviation
0 to 10,000
1 refer-
ence
unit
0
All
Immedi-
ately
Tuning
Pn11F
2
Position Integral Time
Constant
0 to 50,000
0.1 ms
0
All
Immedi-
ately
Tuning
Pn121
2
Friction Compensation
Gain
10 to 1,000
1%
100
All
Immedi-
ately
Tuning
Pn122
2
Second Friction Com-
pensation Gain
10 to 1,000
1%
100
All
Immedi-
ately
Tuning
Pn123
2
Friction Compensation
Coefficient
0 to 100
1%
0
All
Immedi-
ately
Tuning
Pn124
2
Friction Compensation
Frequency Correction
-10,000 to
10,000
0.1 Hz
0
All
Immedi-
ately
Tuning
Pn125
2
Friction Compensation
Gain Correction
1 to 1,000
1%
100
All
Immedi-
ately
Tuning
Pn131
2
Gain Switching Time 1
0 to 65,535
1 ms
0
All
Immedi-
ately
Tuning
Pn132
2
Gain Switching Time 2
0 to 65,535
1 ms
0
All
Immedi-
ately
Tuning
Pn135
2
Gain Switching Waiting
Time 1
0 to 65,535
1 ms
0
All
Immedi-
ately
Tuning
Pn136
2
Gain Switching Waiting
Time 2
0 to 65,535
1 ms
0
All
Immedi-
ately
Tuning
Pn139
2
Automatic Gain Switch-
ing Selections 1
0000 hex to
0052 hex
−
0000
hex
All
Immedi-
ately
Tuning
Pn13D
2
Current Gain Level
100 to 2,000
1%
2000
All
Immedi-
ately
Tuning
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.
X
Gain Switching Selection
0
Use manual gain switching.
The gain is switched manually with the /G-SEL (Gain Selection) signal.
1
Reserved setting (Do not use.)
2
Use automatic gain switching pattern 1.
The gain is switched automatically from the first gain to the second gain when
switching condition A is satisfied. The gain is switched automatically from the
second gain to the first gain when switching condition A is not satisfied.
n.
X
Gain Switching Condition A
0
/COIN (Positioning Completion Output) signal turns ON.
1
/COIN (Positioning Completion Output) signal turns OFF.
2
/NEAR (Near Output) signal turns ON.
3
/NEAR (Near Output) signal turns OFF.
4
Position reference filter output is 0 and reference pulse input is OFF.
5
Position reference pulse input is ON.
n.
X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)