13.4 Utility Function (Fn
) Operations on the Panel Operator
13.4.13 Autotune Motor Current Detection Signal Offset (Fn00E)
13-21
13
Panel Displays and Panel Operator Pr
ocedur
es
13.4.13 Autotune Motor Current Detection Signal Offset (Fn00E)
Refer to the following section for information on this utility function other than the procedure.
5
Press the
UP
Key or
DOWN
Key to adjust the gain.
6
Press the
DATA/SHIFT
Key. The display shown on the
left will appear again.
7
Press the
MODE/SET
Key. The display will change
from the monitor output for channel 1 to the monitor
output for channel 2.
8
Press the
DATA/SHIFT
Key. The gain adjustment will
be displayed as shown on the left.
9
Press the
UP
Key or
DOWN
Key to adjust the gain.
10
Press the
DATA/SHIFT
Key for approximately one sec-
ond.
Ch2-G
will be displayed, and then
Fn00D
will be
displayed again.
Continued from previous page.
Step
Panel Display after
Operation
Keys
Operation
MODE/SET
DATA/
MODE/SET
DATA/
MODE/SET
DATA/
MODE/SET
DATA/
MODE/SET
DATA/
MODE/SET
DATA/
Step
Panel Display after
Operation
Keys
Operation
1
Press the
MODE/SET
Key to enter Utility Function
Mode.
2
Press the
UP
Key or
DOWN
Key to display
Fn00E
.
3
Press the
DATA/SHIFT
Key for approximately one sec-
ond. The display shown at the left will appear.
4
Press the
MODE/SET
Key to perform automatic off-
set-signal adjustment. When the adjustment has been
completed,
donE
will flash on the display, and then the
display shown on the left will appear again.
5
Press the
DATA/SHIFT
Key for approximately one sec-
ond to return the display to
Fn00E
.
MODE/SET
DATA/
MODE/SET
DATA/
MODE/SET
DATA/
MODE/SET
DATA/
MODE/SET
DATA/