13.4 Utility Function (Fn
) Operations on the Panel Operator
13.4.14 Manually Adjust Motor Current Detection Signal Offset (Fn00F)
13-22
13.4.14 Manually Adjust Motor Current Detection Signal Offset
(Fn00F)
Refer to the following section for information on this utility function other than the procedure.
*
Examples of the Amount of Change to Adjust Offsets
•
First time: 10 units at a time
•
Second time: 5 units at a time
•
Third time: 1 unit at a time
The above values are guidelines. Vary the amount of change and the number of repetitions according to your sys-
tem.
Step
Panel Display after
Operation
Keys
Operation
1
Press the
MODE/SET
Key to enter Utility Function
Mode.
2
Press the
UP
Key or
DOWN
Key to display
Fn00F
.
3
First you adjust the offset for phase U (
Cu1-o
). Press
the
DATA/SHIFT
Key for approximately one second.
The display shown at the left will appear.
4
Press the
DATA/SHIFT
Key. The amount of offset for
phase U will be displayed.
5
Press the
UP
Key or
DOWN
Key to change the
amount of offset. Change the setting by approximately
10 units at a time in the direction that reduces the
torque ripple to find the value that minimizes the torque
ripple, and set that value.
Adjustment range: -512 to +511
6
Press the
DATA/SHIFT
Key. The display shown on the
left will appear again.
7
Next you adjust the offset for phase V (
Cu2-o
). Press
the
MODE/SET
Key for approximately one second.
The display shown at the left will appear.
8
Press the
DATA/SHIFT
Key. The amount of offset for
phase V will be displayed.
9
Press the
UP
Key or
DOWN
Key to change the
amount of offset. In the same way as for the phase-U
adjustment, change the setting by approximately 10
units at a time in the direction that reduces the torque
ripple to find the value that minimizes the torque ripple,
and set that value.
Adjustment range: -512 to +511
10
Press the
DATA/SHIFT
Key for approximately one sec-
ond.
Cu2-o
will be displayed, and then
Fn00F
will be
displayed again.
11
Reduce the amount by which you change the offsets each time and repeat steps 3 to 10
*