5.3 Monitoring Machine Operation
5.3.2 Alarm Monitor
5-41
5
Debugging Programs
Status
If an alarm or a warning occurs, the alarm or warning status will be shown on the Alarm Monitor
Tab Page in the following way:
Displaying Alarms and Warnings
If an alarm or a warning occurs, double-click the axis where the alarm or warning occurred to
display the Alarm/Warning Dialog Box.
Troubleshooting Alarms and Warnings
When an alarm occurs, the status will change to
. When a warning occurs, the sta-
tus will change to
.
Click the status indicator to display the Alarm/Warning Dialog Box to see details on the alarm
or warning.
This section uses a SERVOPACK Communications Error as an example to describe what to do
when an alarm or warning occurs.
Icon
Name
Function
No Alarm
No alarm or warning has occurred.
Occurred
Alarm: An alarm has occurred.
Occurred
A warning has occurred.
No.
Item
Function
Axis name
This row displays the name of the axis. The display takes the fol-
lowing format: Assigned axis number : Comment : Type.
Alarm Clear
This button clears the alarm.
Help
This button displays the manual related to the alarm that occurred:
MP3000 Series MP3200/MP3300 Troubleshooting Manual
(Manual
No.: SIEP C880725 01).
Refresh
This button updates the contents of the Alarm/Warning Dialog Box.
Alarms/warnings display
Displays the parameter name, the bit number, and the status.
This area shows the alarm and warning information bit by bit for
each Motion Module.
Close
This button closes the Alarm/Warning Dialog Box.