3.6 Device-specific Settings
3.6.2 Detailed Module Settings
3-28
ST #
This is the station number.
The number of rows that is displayed corresponds to the number of slave stations that is set on
the Transmission Parameters Tab Page.
This number is automatically assigned.
ADR
Set the station address of the slave station.
When the local station is set as a slave station, the address specified on the Transmission
Parameters Tab Page is displayed.
•
Setting range: 03 to EF hex
ExADR
Set the individual extended addresses when multi-station modules (multi-slaves) are grouped
together as a single node.
This box is displayed when the
Display Expansionist Address
Button is clicked, and is hid-
den when the
Omit Expansionist Address
Button is clicked.
•
Setting range: 03 to EF hex
•
Setting the Extended Address
Extended addresses are set in succession from extended address 00 hex.
The following figure shows an example of how to set extended addresses.
VENDOR
Set the vendor name of the device.
•
Settings: Yaskawa Electric Co., **** Vendor
Set the extended address in
order starting from 00 hex: 01
hex, 02 hex, etc.