8-2
165553-1CD
HW1482183
8
Specific I/O Signals
8.2 Specific Output Signals “5xxxx”
Conveyor Synchronized
Funciton with Shift
Functions
51410: SYMOVJ in Execution
Indicates that the move instruction “SYMOVJ” for the conveyor
synchronized motion is being executed.
51420: Conveyor Speed Down
Indicates that the conveyor speed falls below the lower limit of
the speed that is set in the Conveyor Condition File.
51430 to 51432: Disconnection Detected
Indicates the detected disconnection of the conveyor pulse
signals. Each specific output signal corresponds to the following
Conveyor Condition Files.
Conveyor Condition File No. 1: 51430
Conveyor Condition File No. 2: 51431
Conveyor Condition File No. 3: 51432
State
State
State
95 of 98