![YASKAWA Motoman DX200 Скачать руководство пользователя страница 74](http://html.mh-extra.com/html/yaskawa/motoman-dx200/motoman-dx200_instructions-manual_907282074.webp)
5
Conveyor Monitoring Displays for the Shift Functions
5.1 CV (SYNCHRONIZATION) MONITOR Display
5-4
165553-1CD
HW1482183
Conveyor Synchronized
Funciton with Shift
Functions
Execute “SYNCHRONIZATION SWITCH” switches the objective
workpiece to the next workpiece as shown in the figure below.
NOTE
•
The information of the workpiece for current
synchronization is deleted by the execution of
“SYNCHRONIZATION SWITCH” and UNDO operation
is not possible.
Observe the above precaution when
“SYNCHRONIZATION SWITCH” is executed.
•
“SYNCHRONIZATION SWITCH” is valid only when two
or more workpieces are in the conveyor synchronized
section. Do not execute “SYNCHRONIZATION
SWITCH” operation when only one workpiece is in the
conveyor synchronized section. Doing so causes an
alarm because no workpiece exists to be switched.
Manipulator start position
Conveyor moving direction
3
Manipulator
2
1
Conveyor synchronized section
Shift section
4
Workpiece for
synchronization after
having executed
"SYNCHRONIZATION
SWITCH"
74 of 98