![YASKAWA Motoman DX200 Скачать руководство пользователя страница 19](http://html.mh-extra.com/html/yaskawa/motoman-dx200/motoman-dx200_instructions-manual_907282019.webp)
1-4
165553-1CD
HW1482183
1
Conveyor Synchronized Function with Shift Functions
1.4 WORK IN/NOT Shift Function
Conveyor Synchronized
Funciton with Shift
Functions
1.4
WORK IN/NOT Shift Function
In the system that workpieces are conveyed in skits, the WORK IN/NOT
detecting limit switch is activated when a skit passes, and the DX200
reads whether a workpiece is in or not from the predefined general-
purpose input signal.
When the WORK IN/NOT detecting limit switch is not installed near the
manipulator, the second workpiece may pass the WORK IN/NOT
detecting limit switch before the first workpiece, which passed the WORK
ID detecting limit switch, enters the conveyor synchronized section.
The DX200 manages the WORK IN/NOT information obtained through the
WORK IN/NOT detecting limit switch. When the DX200 receives the
information that a workpiece is in the skit, the DX200 starts the job for the
workpiece to move the manipulator in synchronization with the conveyor.
For the above control, the WORK IN/NOT shift function manages up to 99
skit data in the section from the WORK IN/NOT detecting limit switch to
the reference workpiece for synchronization start.
•
Setting image of the shipment before DN1.60-00
•
Setting image of the new shipment at DN1.60-00 or later
Manipulator start position
Conveyor moving direction
WORK IN/NOT
detecting limit switch
2
3
1
0
0
Conveyor synchronized section
DX200
Reference workpiece for
synchronization start
WORK IN/NOT shift distance
Start shift distance
Manipulator start position
Conveyor moving direction
WORK IN/NOT
detecting limit switch
2
3
1
0
0
Conveyor synchronized section
DX200
Reference workpiece for
synchronization start
WORK IN/NOT shift distance
Start shift distance
19 of 98