![YASKAWA Motoman DX200 Скачать руководство пользователя страница 59](http://html.mh-extra.com/html/yaskawa/motoman-dx200/motoman-dx200_instructions-manual_907282059.webp)
3-17
165553-1CD
HW1482183
3
Teaching
3.8 Job Examples
Conveyor Synchronized
Funciton with Shift
Functions
The system variables are defined as follows:
$I000 to $I005: Stores the WORK IN/NOT shift completion status.
$I000: Corresponds to the WORK IN/NOT characteristic file 1.
to to
$I005: Corresponds to the WORK IN/NOT characteristic file 6.
$I006 to $I011: Stores the WORK ID shift completion status.
$I006: Corresponds to the WORK ID characteristic file 1.
to to
$I011: Corresponds to the WORK ID characteristic file 6.
$I012 to $I017: Stores the first WORK IN/NOT information
$I012: Corresponds to the WORK IN/NOT characteristic file 1.
to to
$I017: Corresponds to the WORK IN/NOT characteristic file 6.
$I018 to $I023: Stores the first WORK ID information
$I018: Corresponds to the conveyor WORK ID characteristic file 1.
to to
$I023: Corresponds to the conveyor WORK ID characteristic file 6.
Manipulator start position
Conveyor moving direction
3
Manipulator
Conveyor synchronized section
4
Reference Workpiece for
current synchronization
2
1
WORK ID shift section
WORK IN/NOT shift section
I006
I000
After executing CVQUE, when the next reference
workpiece for synchronization start passes the
WORK ID shift section, sets the WORK ID shift
completion status (1) to the system variable $I006.
After executing CVQUE, when the next reference
workpiece for synchronization start passes
the WORK IN/NOT shift section, sets the
WORK IN/NOT shift completion status (1) to the
system variable $I000.
Start shift section
WORK IN/NOT queue
1
WORK ID queue
2
3
4
5
1
2
3
4
5
I012
I018
After executing CVQUE, sets the WORK
IN/NOT information on the head of queue to
the system variable $I012.
After executing CVQUE, sets the WORK ID
information on the head of queue to the system
variable $I018.
59 of 98