5
Conveyor Monitoring Displays for the Shift Functions
5.4 CV WORK IN/NOT SHIFT STATUS Display
5-14
165553-1CD
HW1482183
Conveyor Synchronized
Funciton with Shift
Functions
5.4.1 Deleting a Conveyor WORK IN/NOT Shift Data
*Cannot be used on new models shipped with version DN1.60-00 or later.
Delete a conveyor WORK IN/NOT shift data in the following manner.
Press the area key
Select {DATA}
Select “CLEAR DATA”
1)
Move the
cursor to “YES” and press [ENTER]
1 The following display appears.
NOTE
•
While power is supplied to the DX200, the DX200
manages and updates automatically all the conveyor
data regardless of the operation mode. Accordingly,
deleting data while the conveyor is moving does not
cause a problem. However, it may cause a malfunction
due to inconsistency between the actual conveyor
status and the DX200 conveyor data in the following
cases:
– - The conveyor moves while power is not supplied to
the DX200 or during the DX200 start sequence.
– - A momentary power failure occurs during operation
in play mode.
– - The virtual conveyor mode is set with the setting
“Ignorance of shift distance in virtual mode.”
•
“CLEAR DATA” operation deletes the shift data on the
currently active display. Delete a start shift data on the
start shift data display, a WORK ID shift data on the
WORK ID shift display, and a WORK IN/NOT shift data
on the WORK IN/NOT shift display respectively. Delete
unnecessary shift data according to the system
configuration.
84 of 98