![YASKAWA Motoman DX200 Скачать руководство пользователя страница 53](http://html.mh-extra.com/html/yaskawa/motoman-dx200/motoman-dx200_instructions-manual_907282053.webp)
3-11
165553-1CD
HW1482183
3
Teaching
3.6 Teaching After Interruption of Synchronized Motion in Playback
Operation
Conveyor Synchronized
Funciton with Shift
Functions
Proceed the rest of the teaching in the same manner as the normal teaching.
To use a move instruction for synchronizing to the conveyor after having
changed to the standard interpolation mode, the operation to select the
interpolation mode for conveyor synchronized move instruction is necessary.
3.6
Teaching After Interruption of Synchronized Motion in
Playback Operation
After the synchronized motion is interrupted by a hold operation or
switching to teach mode during playback operation, another conveyor
home-position cannot be registered since no conveyor home-position
input signal is accepted. At this moment, the tracking status in the
conveyor tracking display is “ON” (marked with “
●
“).
In this case, another conveyor home-position can be registered by either
of the following operations.
(1) Add a step or change the step after interruption of synchronized
motion
(2) Perform another teaching (for other workpiece)
For the details of the above operations, refer to section 5.6 “Teaching After
Interruption of Playback in Synchronized Operation” of “DX200 OPTIONS
INSTRUCTION FOR CONVEYOR SYNCHRONIZED FUNCTION.”
= SYMOVL V=100.0 CV#(1) CTP=1000.000
0005
NOTE
When the start shift function is not used, as long as the
conveyor synchronized operation is not being performed, a
conveyor home position input signal is accepted and the
conveyor home-position is updated.
Therefore, even though teaching is made on the same
conveyor position, if the conveyor home-position limit switch
turns ON inadvertently, the conveyor position data will be
changed.
If there is a risk that the conveyor home-position limit switch
is turned ON inadvertently, perform a FWD key operation
for that step after programming a move instruction for
conveyor synchronized motion such as SYMOVL and
SYMOVC.
This starts the conveyor synchronized operation so that the
conveyor home-position will not be changed even if the
conveyor home-position limit switch turns ON.
In this case, execute a SYEND instruction at the end of
teaching to cancel the synchronization.
53 of 98