![YASKAWA Motoman DX200 Скачать руководство пользователя страница 24](http://html.mh-extra.com/html/yaskawa/motoman-dx200/motoman-dx200_instructions-manual_907282024.webp)
2
Conveyor Condition File
2.1 Conveyor Condition File
2-4
165553-1CD
HW1482183
Conveyor Synchronized
Funciton with Shift
Functions
(13) AVERAGED TRAVEL TIME (0 to 3000 ms)
Set a time to average the travel amount so that the manipulator moves
smoothly at the sudden change of the conveyor speed.
When using the conveyor with large pulsation, set the value between
300 and 500. If this setting is not used, set to “0.”
(14) RESET SIG. MONITOR (0 to 65535 ms)
If no encoder reset signal for a specified conveyor has been input when
the SYSTART instruction is carried out, set the amount of time to wait
for the conveyor home-position input signal.
If the actual waiting time is greater than the setting, the SYSTART
instruction is aborted and the next instruction is carried out. Prepare the
job so that the manipulator takes retreat motion by internal status.
When “0” is set, the system waits for the conveyor home-position input
signal without being interrupted by the time limit for encoder reset signal
monitoring.
(15) CV SPEED DOWN MODE
(EXECUTE/ALARM/PAUSE JOB/JOB INTERRUPTION AFTER
OPERATION)
Specify the action of the manipulator when the conveyor speed is
lowered below the conveyor speed lower limit set in (16).
• EXECUTE
Regardless of the conveyor speed, the manipulator executes the job.
When the conveyor stops, the manipulator continues the synchronized
motion with the conveyor moving at the speed “0.”
• ALARM
When the conveyor average speed becomes below the set value in (16)
for 0.1 second or more, an alarm occurs and the manipulator stops.
• PAUSE JOB
When the conveyor average speed becomes below the set value in (16)
for 0.1 second or more, the job execution is interrupted (only the move
instructions are suppressed) and the manipulator performs only the
follow-up motion. When the conveyor speed recovers to the set value in
(16) or higher, the job execution is re-started.
(16) CV LOWER LIMIT SPEED (0 to 65535 mm/s)
When a mode other than “EXECUTE” is selected in (15), set the
conveyor speed lower limit by which the manipulator takes the
respective action.
Speed
Speed
Time
Time
Conveyor
Manipulator
When "0" is set
When "200" is set
24 of 98