![YASKAWA Motoman DX200 Скачать руководство пользователя страница 49](http://html.mh-extra.com/html/yaskawa/motoman-dx200/motoman-dx200_instructions-manual_907282049.webp)
3-7
165553-1CD
HW1482183
3
Teaching
3.1 Registering Instructions
Conveyor Synchronized
Funciton with Shift
Functions
Format
CVQUE CV#(1)
Conveyor condition file number
Set the conveyor condition file number to be used.
3.1.5 Interpolation Mode for Conveyor Synchronized Motion
The interpolation mode for conveyor synchronized move instruction at
teaching differs from that for the standard move instruction. Switch the
interpolation mode in the manner described below.
Once the conveyor positions at teaching are registered, they must be
properly set up in relation to the conveyor home-position (the position
where the conveyor home-position limit switch turns ON.)
Switching the Interpolation Mode
Press [SHIFT] + [MOTION TYPE]. The interpolation mode displayed in
the input buffer line switches between the standard interpolation and the
interpolation for synchronized motion.
Then, each time [MOTION TYPE] is pressed, the interpolation mode
changes as SYMOVJ
→
SYMOVL
→
SYMOVC.
NOTE
For the shipment before DN1.60-00, when the CVQUE
instruction is executed, the first information of the WORK ID
shift data and WORK IN/NOT shift data are set to the
system variables and deleted from each shift data.
For the new shipment at DN1.60-00 or later, even if the
CVQUE instruction is executed, the first information of the
WORK ID shift data and WORK IN/NOT shift data are not
set to the system variables, but they are deleted from each
shift data.
Pay attention to the execution timing of CVQUE instruction
when preparing a job.
MOVL(Standard interporation)
SYMOVL(Interporation for
synchronized motion)
= MOVL V=66
= SYMOVL V=66 CV#(1)
49 of 98