![YASKAWA Motoman DX200 Скачать руководство пользователя страница 70](http://html.mh-extra.com/html/yaskawa/motoman-dx200/motoman-dx200_instructions-manual_907282070.webp)
4
Playback
4.8 Detection of the Position beyond the Specified Maximum-workpiece-
position
4-4
165553-1CD
HW1482183
Conveyor Synchronized
Funciton with Shift
Functions
4.8
Detection of the Position beyond the Specified Maximum-
workpiece-position
When a workpiece passes over the specified point (MAX. WORK
POSITION) on the conveyor of the synchronized section without
execution of the CVQUE instruction or the switching of workpieces, the
position information, WORK ID information, and WORK IN/NOT
information of the workpiece are automatically deleted from the job queue
data.
Set the maximum workpiece position in the sensor parameter SxE13.
3
4
n-1
2
1
n
Max. workpiece
position
Max. workpiece position
Workpiece shift distance (WORK ID)
WORK ID
detecting
limit switch
Shift completion position
(STP=0)
Conveyor moving direction
"TOP" of the synchronized
section (WORK ID)
Workpiece No.2
position
Because the workpiece No.1
passed over the maximum
workiece position, the
information for the workpiece
No.1 is deleted.
Workpiece No.3
position
70 of 98