3.5 Preparing IP66/NEMA 4X, UL Type 4X Enclosure Drives for
Wiring
u
Select Cable Gland
Specific cable glands and gland plate covers are not listed for North America.
lists the enclosure conduit hole
dimensions by drive model. Use this table to select cable glands or gland plate covers from a local supplier. Use UL approved
cable glands or gland cover plates with NEMA 4X, UL Type 4X, or IP66 integrity for all drive conduit holes. Cable glands
or gland plate covers are supplied by the customer.
Table 3.1 Conduit Hole Dimensions
Voltage Class
Model
Main Circuit
Control Circuit
Conduit Hole Diameter mm (in)
Number of
Holes
Hole Diameter
mm (in)
Total Holes
Input Holes
Output Holes Option Holes
Single-Phase
200 V Class
BV0006G
28 (1.10)
28 (1.10)
28 (1.10)
1
22 (0.87)
3
BV0010G
BV0012G
Three-Phase
200 V Class
2V0006G
28 (1.10)
28 (1.10)
28 (1.10)
1
22 (0.87)
3
2V0010G
2V0012G
2V0020G
2V0030G
2V0040G
2V0056G
2V0069G
Three-Phase
400 V Class
4V0002
22 (0.87)
22 (0.87)
22 (0.87)
1
22 (0.87)
3
4V0004
28 (1.10)
28 (1.10)
28 (1.10)
4V0005
4V0007
4V0009
4V0011
4V0018
4V0023
4V0031
4V0038
n
Remove Rubber Bushings and Insert Cable Glands
NOTICE:
Do not pinch or damage the sealing gasket when attaching the front cover. Damage to the gasket may allow moisture or dust to
enter the protective enclosure and damage drive components.
NOTICE:
Do not use silicone sealant with cable glands or front cover to reinforce waterproofing. Corrosive vapors produced by the sealant
can damage circuit boards and compromise the watertight integrity of the protective enclosure.
NOTICE:
Use only the recommended multi conductor cable and use only one cable per cable gland. Attempting to pass more than one wire
through a cable gland create a space between wires that reduces the waterproofing and dustproofing capabilities of the cable gland, and
may damage the drive.
NOTICE:
Properly seal the rubber gasket along the outside of the cable gland. Improper seals may allow water or oil into the drive and
damage components.
Remove the rubber bushings and insert the proper cable glands into the holes and tighten the glands with the locknut.
3.5 Preparing IP66/NEMA 4X, UL Type 4X Enclosure Drives for Wiring